Translate
Text Highlighter

Bookmark

PDF

Share

Report a problem
AMICUS AI
Citation Codes
Equivalent Citations
citation codes
Docket Number
Attorney(S)
Judges
Are you a practicing lawyer?
Enhance your digital presence and reach by creating a Casemine profile.
Upload pleading to use the new AI search
Cites
Cited by
Citation Codes
Equivalent Citations
citation codes
Docket Number
Attorney(S)
Judges
Smart Summary

Factual and Procedural Background

This appeal arises from a decision of the Patent and Trademark Office (PTO) Board of Appeals affirming the rejection of claims 1, 2, and 3 of an application for a "Rotating Biological Contactor Apparatus" as obvious under 35 U.S.C. § 103 in view of the prior art patent to El-Naggar. The appellant's invention involves a wastewater treatment device characterized by a specific ratio of tank volume to contactor area (about 0.12 gallons per square foot), which appellant argues is an optimum value maximizing treatment capacity. The PTO examiner and board found the claims obvious, relying on El-Naggar's teachings and reasoning that the optimum ratio would have been obvious to try. The court here reviews that decision on appeal.

Legal Issues Presented

  1. Whether the claimed invention, specifically the ratio of tank volume to contactor area of about 0.12 gallons per square foot and its inherent property of maximizing treatment capacity, would have been obvious under 35 U.S.C. § 103 in light of the prior art El-Naggar patent.
  2. Whether the concept of "obvious to try" experiments, involving varying parameters without prior recognition of their effect, satisfies the standard of obviousness under 35 U.S.C. § 103.

Arguments of the Parties

Appellant's Arguments

  • The claimed ratio of tank volume to contactor area (about 0.12 gal./sq. ft.) is an optimum value that maximizes treatment capacity, a property not disclosed or suggested by El-Naggar.
  • El-Naggar’s patent does not recognize tank volume as a factor affecting treatment capacity, nor does it suggest experiments to determine an optimum volume-to-area ratio.
  • The PTO's reliance on "obvious to try" is misplaced because such a standard does not meet the statutory requirement of obviousness under 35 U.S.C. § 103.

Commissioner of Patents' Arguments (PTO and Board)

  • El-Naggar teaches the basic device structure and suggests increasing contactor area to improve efficiency, implying the concept of optimizing parameters.
  • The examiner assumed tank volume remains constant while increasing contactor area, making the claimed ratio an obvious result of routine experimentation.
  • The PTO and minority argue it is obvious to try varying all parameters to optimize system effectiveness, even without prior recognition of their effect.

Table of Precedents Cited

Precedent Rule or Principle Cited For Application by the Court
In re Davies, 475 F.2d 667, 177 USPQ 381 (CCPA 1973) Consideration of invention as a whole including inherent properties in obviousness analysis. The court applied this to include the claimed ratio and its inherent property of maximizing treatment capacity in the obviousness inquiry.
In re Papesch, 315 F.2d 381, 137 USPQ 43 (CCPA 1963) Obviousness must be assessed on the invention as a whole, not isolated parts. Supported the court’s approach to consider the ratio value together with its inherent property.
In re Tomlinson, 363 F.2d 928, 150 USPQ 623 (CCPA 1966) "Obvious to try" is not the standard for obviousness under 35 U.S.C. § 103. The court rejected the PTO’s reliance on "obvious to try" reasoning to support obviousness.
In re Dien, 371 F.2d 886, 152 USPQ 550 (CCPA 1967) Reinforces requirement to consider invention as a whole in obviousness analysis. Used to support the court’s holistic approach.
In re Wiggins, 397 F.2d 356, 158 USPQ 199 (CCPA 1968) Obviousness requires more than routine experimentation; must consider invention as a whole. Supported court’s rejection of PTO’s overemphasis on routine data gathering.
In re Saether, 492 F.2d 849, 181 USPQ 36 (CCPA 1974) Unexpected results from optimization may negate obviousness despite routine experimentation. Used to distinguish this case as an exception where the optimized parameter was not recognized as effective by prior art.
In re Aller, 220 F.2d 454, 105 USPQ 233 (CCPA 1955) Discovery of an optimum value of a known variable is normally obvious. The court acknowledged this rule but found this case to be an exception due to the unrecognized effect of the parameter.
In re Kronig, 539 F.2d 1300, 190 USPQ 425 (CCPA 1976) Obviousness does not require absolute predictability of results. Referenced in dissent to argue that routine experimentation suffices for obviousness.

Court's Reasoning and Analysis

The court began by defining the invention as a whole to include both the claimed ratio of tank volume to contactor area (about 0.12 gal./sq. ft.) and its inherent property of maximizing treatment capacity. It emphasized that obviousness must be assessed on the invention as a whole, not merely on isolated features.

The court found that El-Naggar’s patent, while teaching the basic structure of the device, did not disclose or suggest the critical ratio or recognize the importance of tank volume in maximizing treatment capacity. El-Naggar’s data lacked any discussion of tank volume, and the experiments he described did not reveal the relationship between tank volume and treatment capacity.

The PTO’s reasoning assumed fixed tank volume and that increasing contactor area would lead to the claimed ratio, but these assumptions were speculative and not supported by the record. The court noted that without recognition of tank volume as a result-effective variable, there was no basis in El-Naggar for the specific optimization claimed.

The court rejected the PTO’s reliance on the notion that it would have been "obvious to try" varying parameters to optimize results, explaining that "obvious to try" is not the legal standard for obviousness under 35 U.S.C. § 103. The court stressed that routine experimentation after an invention’s existence is recognized does not render the invention obvious if the invention’s critical properties were not previously recognized.

Finally, the court acknowledged the general rule that discovering an optimum value of a known variable is usually obvious but found this case to be an exception because the parameter optimized (tank volume ratio) was not recognized by the prior art to be effective in producing the claimed result.

Holding and Implications

The court REVERSED the decision of the PTO Board of Appeals, holding that the claimed invention was not obvious under 35 U.S.C. § 103.

As a direct consequence, the appellant’s claims are no longer rejected on obviousness grounds, allowing further prosecution or potential allowance of the patent. The court’s decision clarifies that the mere fact of routine experimentation to optimize parameters is insufficient to establish obviousness when the prior art does not recognize the critical variable’s effect. No new precedent beyond this application of existing standards was established.

APPLICATION OF RONALD L. ANTONIE.

BALDWIN, Judge.

This is an appeal from a decision of the Patent and Trademark Office (PTO) Board of Appeals (board) affirming the rejection of claims 1, 2 and 3 of an application for "Rotating Biological Contactor Apparatus" as obvious under 35 U.S.C. § 103 in view of El-Naggar. We reverse.

Serial No. 331,796, filed February 12, 1973.

"Method of Treatment of Sewage by Bio-Oxidation and Apparatus Therefor," U.S. Patent No. 3,335,081, issued August 8, 1967.

The Invention

Appellant claims a wastewater treatment device in which wastewater is continuously passed through a tank. Semi-immersed contactors (disks) are continuously rotated to aerate their immersed portions and thereby to aerate both microorganisms that grown on the contactors and the wastewater itself. For this discussion, several variables are important in this device. "Throughput" is the volume of wastewater per unit time (gal./day) which the device must treat. "Contactor area" is the total area of the contactors which is exposed to the wastewater as the contactors are rotated (sq. ft.). "Tank volume" is the actual volume of liquid in the tanks in which the contactors rotate (gal.). The ratio of throughput to contactor area (gal./day/sq. ft.) is called the "hydraulic loading." Two concepts of effectiveness of the equipment are important in this discussion. The primary prior art reference uses the term "efficiency" to denote the percent impurity reduction which a given set-up of the device achieves and we shall so use the term. Appellant uses the term "maximum treatment capacity" to denote when a unit of contactor area is providing maximum "efficiency" for a given "throughput" or maximum "throughput" for a given "efficiency." It is essential to understand the distinction between "efficiency," a matter of ultimate effectiveness independent of the efficiency of the equipment, and "treatment capacity," a matter of the efficiency or effectiveness of a unit of contactor area. The latter is more properly associated with the normal use of the term "efficiency" denoting maximum result from a limited resource.

Appellant's claimed device has a ratio of tank volume to contactor area of 0.12 gal./sq. ft. Appellant maintains that this ratio is the most desirable or optimum for all set-ups of the device in the sense that using a lower value gives lower "treatment capacity" and using a greater value gives no increase in "treatment capacity," merely increasing costs. Thus, the value is optimum in that it maximizes "treatment capacity" so that the effectiveness of a given contactor is maximized.

Claims 1 and 2 recite "at least about 0.12" while claim 3 recites "about 0.12."

The Prior Art

El-Naggar teaches the basic structure of the device claimed by appellant but is silent regarding quantitative design parameters other than to give data on a single example, which data was apparently complete except for any discussion of "tank volume." El-Naggar stated the "efficiency" (obviously referring to the purity of the output) could be increased to 95% by increasing the area of the contactor.

The Rejection

The examiner rejected the claims as obvious under 35 U.S.C. § 103, noting that the basic device in question is old as taught by El-Naggar. While the ratio of tank volume to contactor area of 0.12 gal./sq. ft. is not disclosed in El-Naggar, the examiner reasoned that the disclosure of El-Naggar would make a device with that optimum value obvious. The examiner noted that El-Naggar suggests increasing the "efficiency" (degree of purification) of his device by increasing the contactor area while apparently keeping the "throughput" constant, that is, reducing the "hydraulic loading." The examiner then assumed that El-Naggar teaches keeping the tank volume constant while increasing the contactor area. Thus, the examiner argued that the idea of increasing tank volume to surface area to increase efficiency is taught and that working out the value for optimum efficiency is mere mechanical experimentation. The board accepted the examiner's reasoning.

OPINION

In determining whether the invention as a while would have been obvious under 35 U.S.C. § 103, we must first delineate the invention as a whole. In delineating the invention as a whole, we look not only to the subject matter which is literally recited in the claim in question (the ratio value) but also to those properties of the subject matter which are inherent in the subject matter and are disclosed in the specification. In re Davies, 475 F.2d 667, 177 USPQ 381 (CCPA 1973). In this case, the invention as a whole is the ratio value of 0.12 and its inherent and disclosed property. That property is that the described devices designed with the ratio will maximize treatment capacity regardless of the values of the other variables in the devices. Just as we look to a chemical and its properties when we examine the obviousness of a composition of matter claim, it is this invention as a whole, and not some part of it, which must be obvious under 35 U.S.C. § 103. Cf. In re Papesch, 50 CCPA 1084, 315 F.2d 381, 137 USPQ 43 (1963).

The controlling question is simply whether the differences (namely the value of 0.12 and its property) between the prior art and appellant's invention as a whole are such that appellant's invention as a whole would have been obvious. The answer is no. It is impossible to recognize, from the experiment taught by El-Naggar, that "treatment capacity" is a function of "tank volume" or the tank volume-to-contactor area ratio. Recognition of this functionality is essential to the obviousness of conducting experiments to determine the value of the "tank volume" ratio which will maximize treatment capacity. Such functionality can only be determined from data representing either efficiency at varying tank volume, fixed throughput, and fixed contactor area or throughput at varying tank volume, fixed efficiency, and fixed contactor area. Each of these experiments represents treatment capacity with fixed contactor area but varying tank volume. This sort of experiment would not be suggested by the teachings of El-Naggar since he was not trying to maximize or control "treatment capacity." The experiments suggested by El-Naggar do not reveal the property which applicant has discovered, and the PTO has provided us with no other basis for the obviousness of the necessary experiments.

The PTO and the minority appear to argue that it would always be obvious for one of ordinary skill in the art to try varying every parameter of a system in order to optimize the effectiveness of the system even if there is no evidence in the record that the prior art recognized that particular parameter affected the result. As we have said many times, obvious to try is not the standard of 35 U.S.C. § 103. In re Tomlinson, 363 F.2d 928, 53 CCPA 1421, 150 USPQ 623 (1966). Disregard for the unobviousness of the results of "obvious to try" experiments disregards the "invention as a whole" concept of § 103, In re Dien, 371 F.2d 886, 54 CCPA 1027, 152 USPQ 550 (1967) and In re Wiggins, 397 F.2d 356, 55 CCPA 1356, 158 USPQ 199 (1968), and overemphasis on the routine nature of the data gathering required to arrive at appellant's discovery, after its existence became expected, overlooks the last sentence of § 103. In re Saether, 492 F.2d 849, 181 USPQ 36 (CCPA 1974).

The precise nature of the El-Naggar experiment and the nature of the data which would result are rendered hopelessly speculative by El-Naggar's total failure to discuss the critical matter of what is done with the volume of the tank. The PTO appears to assume, as a necessary element of its conclusion, that appellant's ratio is the inevitable result of El-Naggar experiment, and that the tank volume is fixed, apparently because El-Naggar does not suggest changing the tank as additional contactor area is supplied. Even if the same tank were used, the actual liquid volume of the tank could change significantly if 1) the tank has a level control, 2) the tank is not extremely large in comparison to the contactors and 3) the volume-to-area ratio of the contactors themselves is significant. Since these assumptions are not unreasonable, there is serious doubt as to the constant volume of the tank.
Whether one would inevitably arrive at the ratio value of 0.12 or above depends on facts which must be read into El-Naggar, (e.g., the volume of the tank) and on assumptions about the kind of motivation (e.g., the degree of "efficiency" which would be sought). All of this involves, at least on this record, mere speculation. Assuming, as the examiner has, that the tank volume is fixed and the natural motivation is to maximize efficiency, if El-Naggar's equipment has a tank volume to contactor area ratio of less than 0.12, and the resulting efficiency is found wanting, increasing the contactor area to increase "efficiency" will lead away from the claimed ratio.

In In re Aller, 220 F.2d 454, 42 CCPA 824, 105 USPQ 233 (1955), the court set out the rule that the discovery of an optimum value of a variable in a known process is normally obvious. We have found exceptions to this rule in cases where the results of optimizing a variable, which was known to be result effective, were unexpectedly good. In re Waymouth, 499 F.2d 1273, 182 USPQ 290 (CCPA 1974); In re Saether, supra. This case, in which the parameter optimized was not recognized to be a result-effective variable, is another exception. The decision of the board is reversed.

REVERSED.

MILLER, J., concurs in the result.

[16] HERBERT N. MALETZ, Judge,[fn*] dissenting, with whom RICH, Judge, joins. [fn*] Judge of the United States Customs Court sitting by designation pursuant to 28 U.S.C. § 293(d).

With all due respect, I cannot agree with the majority's interpretation of the El-Naggar patent. El-Naggar discloses the same wastewater treatment apparatus as claimed, except for the specific volume-to-surface ratio of .12 gallons per square foot as recited in the claims. However, El-Naggar generally discloses varying the number of disks (column 3, lines 31-35), the number of concentric cylinders (column 4, lines 27-30), or the length of the cylinders (column 4, lines 61-62) in his apparatus in order to optimize results. Given the basic apparatus of El-Naggar and the concept of varying the number of disks in a tank in order to optimize impurity removal, I believe that it would have been well within the capabilities of the chemical engineer of ordinary skill to determine empirically, by routine experimentation, the optimum design ratio which appellant has determined and recited in his claims. That is, El-Naggar set the way, and appellant's work was what any routineer would have accomplished in following the patent teachings.

Appellant urges that the results which he determined empirically by plotting the effect of volume-to-surface ratio on impurity removal, including the specific, optimum design ratio of .12 gallons per square foot, could not have been predicted from El-Naggar. However, obviousness under 35 U.S.C. § 103 does not require absolute predictability, In re Kronig, 539 F.2d 1300, 190 USPQ 425 (CCPA 1976), and it is sufficient here that El-Naggar clearly led the way for the routineer to arrive at the claimed apparatus.

I am in substantial agreement with the board's analysis of this case, and I would affirm the board's decision.

Use AI to get other relevant cases.

Comments

APPLICATION OF ANTONIE
(Aug 18, 1977)