Smart Summary

Structured Summary of the Opinion — Petition No. 26/2006

Factual and Procedural Background

This petition was filed by the petitioner seeking revision of operational parameters and norms used for determination of tariff of Tanda Thermal Power Station (the generating station) for the tariff period 2004–2009. The generating station was transferred by the Government of Uttar Pradesh to the respondent under the Uttar Pradesh Electricity Reforms (Transfer of Tanda Undertaking) Scheme, 2000, on 14.1.2000 for a consideration of Rs. 1000 crore. Power generated from the station is supplied exclusively to the petitioner under an agreement dated 7.1.2000 for 25 years.

The Commission had earlier approved tariff for the period from 14.1.2000 to 31.3.2004 by orders dated 28.6.2002 and 9.4.2003 (in Petition No. 77/2001 and its review). Additional capital expenditure of Rs. 17747 lakh incurred during 2000–2004 on renovation & modernization (R&M) was approved by order dated 24.10.2005 (Petition No. 8/2005), and annual fixed charges were revised accordingly.

On 26.3.2004 the Commission notified the Central Electricity Regulatory Commission (Determination of Tariff) Regulations, 2004, which set operational norms for the period 1.4.2004 to 31.3.2009; relaxed norms for R&M stations (including Tanda TPS) were specified, and the respondent was directed to approach the Commission for revision of norms after completion of R&M works. The respondent did not apply; the petitioner applied for revision, supported by operational data for 2000–2005 and a proposal for new norms.

Legal Issues Presented

  1. Whether the operational norms (target availability, target PLF, station heat rate, auxiliary energy consumption, specific oil consumption) applicable to Tanda TPS for the tariff period 2004–2009 should be revised in light of the R&M works and observed improvement in actual performance.
  2. If revision is warranted, what revised operational norms should be adopted and from what effective date?
  3. Whether the petitioner's ancillary prayers—restriction of recovery of profits to a 14% return on equity (ROE) and recovery of income-tax on incentives/profits exceeding 14% ROE—should be allowed in this proceeding.

Arguments of the Parties

Petitioner's Arguments

  • Extensive R&M works have been carried out, resulting in a marked improvement in the generating station's performance; therefore, operational norms should be revised to reflect the improved performance and to bring them at par with other thermal generating stations.
  • The petitioner notified the respondent (letter dated 21.1.2006) about improved performance post R&M and submitted actual operational data for 2000–2005 supporting proposed norms (including target availability/PLF 80%, station heat rate 2800 kCal/kWh, auxiliary consumption 10.5%, specific oil consumption 2 ml/kWh).
  • The petitioner prayed that recovery of profits be restricted to 14% ROE and that income-tax recovery on incentive/profits exceeding 14% ROE be restricted.

Respondent's Arguments

  • The Commission intended that operational norms be reviewed only after performance improvements were established and sustainable; even though improvement occurred during ongoing R&M, performance was not yet fully sustainable because certain R&M works addressing generic problems remained in progress.
  • It would be premature to revise norms based on improvements arising from short- and medium-term works; respondent accordingly did not apply for revision earlier but furnished operational data when directed.
  • On auxiliary energy consumption (AEC), the respondent explained measurement methodology: energy meter readings were taken on UAT and station transformers and omitted some transformer/generator losses (~0.95%). The station has additional load (three-staged pumping and bearing cooling water system) causing ~0.83% higher AEC compared to certain other stations; when these adjustments are accounted for, comparable stations would have higher effective AEC. Accordingly, respondent proposed an AEC norm of 12.5%.

Table of Precedents Cited

No precedents were cited in the provided opinion.

Court's Reasoning and Analysis

The court examined the material on record and the parties' submissions and proceeded as follows:

  1. Completion of R&M: The court observed from the respondent's data that the initial R&M works were completed by the end of 2003–2004 and that actual operational parameters had substantially improved thereafter, except for auxiliary energy consumption. This supported a need to revisit norms originally applied to the station under the 2004 Regulations.
  2. Comparison with norms and peers: The court compared actual performance figures with (a) the relaxed norms notified for R&M stations and (b) norms applicable to other coal-based thermal stations. It noted that the station achieved high target availability/PLF (about 86.7% in 2004–05 and 86.4% in 2005–06), exceeding the 80% norm applicable to other thermal stations, and that specific secondary fuel oil consumption had fallen to 0.92 ml/kWh—favourable against the 2.0 ml/kWh norm.
  3. Station heat rate: The court noted achieved station heat rates of 2758 kCal/kWh in 2004–05 and 2746–2771 kCal/kWh in 2005–06 at plant load factors of 75% and 86% respectively. It concluded that at an 80% PLF the station could reasonably achieve a heat rate of 2800 kCal/kWh. To allow for degradation over the tariff period, the court applied a degradation factor of 1.02%, resulting in a considered station heat rate norm of 2850 kCal/kWh.
  4. Auxiliary energy consumption: The court reviewed the trend of AEC, which reduced from 19.73% in 2000–01 to 11.88% in 2005–06. The petitioner proposed 10.5%, while the respondent urged 12.5% (explaining metering and station-specific consumption differences). Weighing the data and submissions, the court found a 12% auxiliary energy consumption norm to be reasonable.
  5. Scope of other prayers: On prayers relating to restriction of ROE and tax recovery, the court found that the petitioner had not demonstrated that any recovery by the respondent was outside the terms and conditions of the applicable tariff or Commission approvals. The court observed these are generic issues requiring detailed, multi-stakeholder deliberation and therefore reserved them for consideration by the Commission at an appropriate time.
  6. Remedy for procedural lapse: The court recorded that the respondent had been directed originally to apply for revised norms after R&M completion but failed to do so, forcing the petitioner to file the application. Given these peculiar circumstances, the court directed that the filing fee paid by the petitioner (Rs. 1 lakh) be reimbursed by the respondent.

Holding and Implications

Core Ruling: The petition is disposed of with partial allowance: the court directed revision of operational norms for Tanda TPS and prescribed specific revised norms to apply with effect from 1.4.2007.

Direct holding and orders pronounced by the court:

  • Revised operational norms to apply w.e.f. 1.4.2007:
    • Target Availability: 80%
    • Target PLF: 80%
    • Station Heat Rate Norm: 2850 kCal/kWh
    • Auxiliary Energy Consumption Norm: 12%
    • Specific Fuel Oil Consumption: 2 ml/kWh
  • The office of the Commission is directed to initiate appropriate action to amend Regulation 16 of the 2004 Regulations to give effect to these revised norms.
  • The respondent is directed to file revised calculations supporting energy charge and working capital/interest on working capital for years 2007–2008 and 2008–2009, based on the finally notified revised norms, latest by 31.3.2007.
  • The respondent shall pay to the petitioner the filing fee of Rs. 1 lakh, latest by 28.2.2007, to compensate for not having filed the revision application as previously directed.
  • Other prayers (restriction of ROE to 14% and tax recovery issues) were not allowed in this proceeding: the petitioner had not shown recoveries to be outside applicable tariff terms; these generic issues require broader consideration and may be taken up by the Commission later.
  • Petition No. 26/2006 is disposed of.

Implications:

  • Direct effect: The operational norms for tariff computation of Tanda TPS for the remainder of the 2004–2009 tariff period (as specified) are revised effective 1.4.2007, and the respondent must update tariff-related calculations accordingly.
  • Administrative consequence: Amendment to Regulation 16 will be initiated by the Commission's office to reflect these station-specific norms.
  • No broader legal precedent: The opinion addresses station-specific tariff norm revision and administrative directions. The court did not purport to establish a new general legal doctrine beyond the application of the Regulations and facts of this case; other generic issues raised were left for separate consideration by the Commission.

This summary was prepared strictly from the contents of the provided opinion and does not add or infer facts beyond that text.

    Uttar Pradesh Power Corporation Ltd., Lucknow v. National Thermal Power Corporation Ltd.

    This petition has been filed by the petitioner for revision of operational parameters and norms for determination of tariff of Tanda Thermal Power Station (hereinafter referred to as the generating station), a generating station owned by the respondent, for the period 2004–2009.

    2. Tanda Thermal Power Station was transferred by the Government of Uttar Pradesh to the respondent under the provisions of Uttar Pradesh Electricity Reforms (Transfer of Tanda Undertaking) Scheme, 2000, on 14.1.2000 for a total consideration of Rs. 1000/- crore. The power generated from the generating station is supplied exclusively to the petitioner under an agreement dated 7.1.2000, valid for a period of 25 years.

    3. The Commission approved the tariff of the generating station for the period from 14.1.2000 to 31.3.2004 by order dated 28.6.2002 in Petition No. 77/2001 and by order dated 9.4.2003 in Review Petition No. 2/2003 in Petition No. 77/2001. The fixed charges approved by the Commission based on the gross block of Rs. 60700 lakh (as on 14.1.2000) are as under:

    (Rs. in lakh)

    YEAR 1999-2000 2000-2001 2001-2002 2002-2003 2003-2004 Fixed Charges 18120 17703 16149 15945 15723

    4. The Commission approved additional capital expenditure of Rs. 17747 lakh incurred by the petitioner during the period 2000–2004 on R & M works of the generating station, after its takeover vide order dated 24.10.2005 in Petition No. 8/2005 and further revised the annual fixed charges of the generating station as under:

    (Rs. in lakh)

    YEAR 1999-2000 2000-2001 2001-2002 2002-2003 2003-2004 Fixed Charges 18124 18034 17163 17834 18464

    5. Meanwhile, the Commission notified the Central Electricity Regulatory Commission (Determination of Tariff) Regulations, 2004 (hereinafter referred to as “the said regulations”) on 26.3.2004 Regulation 16 the said regulations laid down the operational norms applicable to the different generating stations for the period 1.4.2004 to 31.3.2009 In case of the generating station which was under R & M, relaxed operational norms are laid down as under:

    Name of Station Target Availability Target PLF Station Heat Rate (kcal/kWh) Auxiliary Energy Consumption Norm (%) Specific Fuel Oil Consumption (ml/kWh) Tanda TPS/440 MW 60% 60% 3000 11.00 3.5

    6. The respondent was, however, directed to approach the Commission for revision of the operational norms of the generating station after completion of the R & M works. In this connection, the relevant part of the order of the Commission dated 29.3.2004 is extracted below:

    “28. With regard to operational norms for Tanda TPS and Talcher TPS, the Commission had missed the same in the draft regulations through oversight. However, this was covered in the order dated 16.1.2004 and it was observed as under:

    “There are two generating stations of NTPC, namely Tanda TPS and Talcher TPS which are having steam turbines of 60 MW and 110 MW. The Commission has finalized operational norms for these generating stations of NTPC recently while dealing with tariff petitions on case-to-case basis. Further, these generating stations are undergoing lot of R & M works and the Commission would not like to review the operational norms till the R & M works are completed. NTPC is directed to come before the Commission with a proposal on the revised operational norms after the completion of R & M works in these generating stations. As such, we hold that the operational norms of station heat rate, auxiliary energy consumption and specific fuel oil consumption prescribed by the Commission for the year 2003–2004 in respect of above two generating stations of NTPC in the tariff orders for the previous tariff period up to 31.3.2004, shall continue to apply during the tariff period 2004–2009 also, till R & M work in these stations is completed.”

    7. Since the respondent did not make any application for revision of operational norms, the application has been made by the petitioner. The petitioner has submitted that due to extensive R & M carried out, the performance of the generating station has improved remarkably, necessitating revision of the operational norms to bring them at par with the other thermal power generating stations. The petitioner has further submitted that it apprised the respondent vide its letter dated 21.1.2006 about the improved performance of the generating station consequent to R & M. The petitioner has submitted the data regarding the actual operational parameters achieved by the generating station, during 2000–2005 and based on the said parameters, has proposed the following norms for consideration and adoption by the Commission for the tariff period 2004–2009, which are at par with the operational norms applicable to other generating stations:

    Parameters Operational 2000-2001 2001-2002 2002-2003 2003-2004 2004-2005 Existing norms Proposed Norms Target availability & target PLF(%) 28 51 64 84 96.6 60 80 Specific oil consumption MI/kWh 38.8 11 2.12 0.92 — 3.5 2 Station heat rate 3764 3363 3137 2846 — 3000 2800 Aux. energy consumption 19.7 16.1 13.78 12.8 — 11 10.5

    8. In addition, the petitioner has prayed to restrict recovery of profits, exceeding 14% ROE and recovery of income-tax on incentive and profits, exceeding 14% ROE.

    9. The respondent in its reply has submitted that the intention of the Commission was to review the operational norms after the performance improvement was established and sustainable. The respondent has submitted that though the operational performance has improved during the ongoing R & M works, the performance is not sustainable till R & M works are completed in all respects. It has been further submitted that certain R & M works to overcome the generic problems of the generating station are currently under progress and it would be premature to revise the norms at this stage because of performance improvements just on completion of short and medium term works.

    10. During the hearing held on 20.6.2006, the respondent was directed to furnish the actual operational parameters achieved by the generating station during the period 2000–2005. Subsequently, the respondent was also asked to furnish the actual operating parameters achieved during the year 2005–2006 and also the reasons for high auxiliary energy consumption. The respondent has furnished the information under affidavits dated 1.8.2006 and 6.10.2006 The data submitted by the respondent is extracted as under:

    Operational Norm 2000-2001 2001-2002 2002-2003 2003-2004 2004-2005 2005-2006 Target Availability/PLF (%) 30.87 54.52 57.58 75.32 86.07 86.4 Heat rate 3764 3365 3137 2846 2758 2746 to 2771 AEC (%) 19.73 16.1 13.84 12.81 12 11.88 Sp. Oil (ml/kWh) 38.87 11.26 2.12 0.92 0.74 0.62

    11. As regards the reasons for high auxiliary energy consumption, the respondent has stated that as a result of continuous efforts made by it since the take-over of the generating station, the auxiliary energy consumption has come down from 23.79% in 2000 to 11.88% in 2005–2006 and compares with the auxiliary energy consumption of similar 210 MW units at Bhatinda and Panipat of 11.24% and 10.34% respectively. It has been stated that the readings are based on the energy meter reading installed on UAT and Station Transformers and did not include the losses in generator transformer, unit auxiliary transformers, station transformers and excitation power, which were about 0.95%. There is higher auxiliary energy consumption of about 0.83% on account of the three-staged pumping and bearing cooling water system provided at the generating station not applicable in case of Bhatinda and Panipat generating stations. The respondent has further submitted that when the additional power consumption of about 0.95% and 0.83% are added to the figures of Bhatinda and Panipat, their auxiliary energy consumptions work out to 13.02% and 12.12% respectively, which were higher than the auxiliary energy consumption of the generating station. It has been submitted that for the reasons explained, normative auxiliary energy consumption of the generating station should be fixed at 12.5%.

    12. We have perused the material on record and considered the submissions of the parties.

    13. The data submitted by the respondent shows that the initial R & M works of the generating station were complete by the end of the year 2003–2004. As a result of R & M actual operational parameters have substantially improved in comparison to the norms notified, except for auxiliary energy consumption. We, therefore, feel that there is a pressing need to revise the operational norms. As may be noticed from para 4 above, there is considerable increase in capacity charges, consequent to completion of R & M, resulting in improvement in performance of the generating station.

    14. It is observed that the generating station has achieved the target availability/plant load factor of 86.7% and 86.4% for the years 2004–2005 and 200506 respectively, which is higher than the norm of 80% fixed for the other thermal power generating stations of the respondent. Similarly, secondary fuel oil consumption has come down to 0.92 ml/kWh from the year 2003–2004, which is favourable as compared to the norm of 2.0 ml/kWh laid down for all coal-based thermal power generating stations. Therefore, there exists a strong case that the norms for target availability, plant load factor and secondary fuel oil consumption applicable to the generating station should be revised to bring them at par with the other coal-based thermal power generating stations.

    15. As regards the gross station heat rate, the generating station has achieved 2758 kCal/kWh during the year 2004–2005 and 2746 kCal/kWh to 2771 kCal/kWh during the year 2005–2006 at the plant load factor of 75% and 86% respectively. As such, corresponding to 80% of plant load factor, it would be possible for the generating station to achieve heat rate of 2800 kCal/kWh. The generating station having been recently renovated, it would be prudent to take a factor of 1.02% to take care of the degradation during the tariff period. After catering for the degradation factor, the station heat rate of 2850 KCal/kWh is considered reasonable and be applied.

    16. As regards the auxiliary energy consumption, the petitioner has submitted that it should be revised to 10.5%, whereas the respondent has urged that for the reasons explained by it, the auxiliary energy consumption may be set at 12.5%. A perusal of the data furnished by the respondent reveals that the actual auxiliary energy consumption has come down from 19.73% in 2000–2001 to 11.88% in 2005–06. Under the circumstances, it may be reasonable to prescribe auxiliary energy consumption norm of 12%.

    17. Accordingly, we decide that the following revised norms should be applicable in respect of the Tanda TPS w.e.f 1.4.2007:

    Target Availability Target PLF Station Heat Rate Norm (kCal/kWh) Auxiliary Energy Consumption Norm (%) Specific Fuel Oil Consumption (ml/kWh) 80% 80% 2850 12% 2

    18. The applicability of the revised norms requires amendment of Regulation 16 of the said regulations. It is directed that the office shall initiate appropriate action for this purpose. The tariff for the period ending 31.3.2009 in respect of the generating station has already been approved. The respondent shall file the revised calculations in support of the energy charge and working capital/interest on working capital for the years 2007–2008 and 2008–2009 based on the revised operational norms, finally notified, latest by 31.3.2007

    19. As regards the other prayers of the petitioner, regarding recovery of profits and income-tax, it is noticed that the petitioner has not made out that any recoveries by the respondent are de hors the terms and conditions of tariff applicable during the period 1.4.2004 to 31.3.2009 or the tariff approved by the Commission, except for making a statement that return on equity needs to be restricted to 14% only. Besides, the issues are generic in nature involving all the stakeholders and require detailed deliberations and in-depth analysis. The issues may be taken up for consideration by the Commission at the appropriate time.

    20. As we have noted above, the respondent was directed to make an application for revision of operational norms after completion of R & M works. The data furnished by the respondent shows considerable improvement in performance during 2004–2005 itself. Certain parameters achieved are no way inferior to other generating stations. However, the respondent did not approach the Commission and this forced the petitioner to make the application. Under these peculiar circumstances, we direct that the filing fee of Rs. One lakh paid by the petitioner shall be paid by the respondent to the petitioner, latest by 28.2.2007

    21. This disposes Petition No. 26/2006.