A.3. - Also see General Code requirements.
S. Specifications
S.1. Design of Indicating and Recording Elements and of Recorded Representations.
S.1.1. Zero Indication.
(a) A weigh-labeler shall be equipped with an indicating or recording element. It
Additionally, a weigh-labeler equipped with an indicating or recording element shall either indicate or record a zero-balance condition and an out-of-balance condition on both sides of zero.
(Amended 2004)
(b) An automatic checkweigher may be equipped with an indicating or recording element.
(c) A zero-balance condition may be indicated by other than a continuous digital zero indication, provided that effective automatic means is provided to inhibit a weighing operation or to return to a continuous digital indication when the device is in an out-of-balance condition.
S.1.1.1. Digital Indicating Elements.
(a) A digital zero indication shall represent a balance condition that is within =
V* scale division.
3 See NIST Handbook 130, Uniform Laws and Regulations In the Area of Legal Metrology and Engine Fuel Quality, Interpretations ami Guidelines paragraph 2,6.11, Good Quantity Control Practices.
(b) A digital indicating device shall either automatically maintain a "center of zero" condition to = W scale division or less, or have an auxiliary or supplemental "center-of-zero" indicator that defines a zero-balance condition to ± !4 scale division or less.
(c) Verification of the accuracy of the center of zero indication to ±
'A scale division or less during
automatic operation is not required on automatic checkweighers.
(Amended 2004)
S.1.2. Value of Division Units. - The value of a division "d" expressed in a unit of weight shall be equal to:
(b) a decimal multiple or submultiple of 1, 2. or 5.
S.1.2.1. Weight Units. - Except for postal scales, indicating and recording elements for shipping and postal applications, and scales used to print standard pack labels. A a device shall indicate weight values using only a single unit of measure. (Amended 2004J
S.1.3. Provision for Sealing.
(a) Automatic Weighing Systems, Except Automatic Checkweighers. - A device shall be designed with provision(s) as specified in Table S.I.3.. "Categories of Device and Methods of Sealing." for applying a security seal that must be broken, or for using other approved means of providing security (e.g., data change audit trail available at the time of inspection), before any change that detrimentally affects the metrological integrity of the device can be made to any electronic mechanism.
(b) For Automatic Checkweighers. - Security seals are not required in applications where it would prohibit an authorized user from having access to the calibration functions of a device.
Table S.1.3. |
Categories of Device and Methods of Sealing |
Categories of Device |
Method of Sealing |
Category 1: No Remote configuration capability'. |
Seal by physical seal or two event counters: one for calibration parameters and one for configuration parameters. |
Category 2: Remote configuration capability, but access is controlled by physical hardware The device shall clearly indicate that it is in the remote configuration mode and record such message if capable of printing in this mode. |
The hardware enabling access for remote communication must be at the device and sealed using a physical seal or two event counters: one for calibration parameters and one for configuration parameters. |
Category 3: Remote configuration capability access may be unlimited or controlled through a software switch (e.g.. password) |
An event logger is required m the device, it must include an event counter (000 to 999). the parameter ID, the date and time of the change, and the new value of the parameter. A printed copy of the information must be available through tire device or through another on-site device. The event logger shall have a capacity to retain records equal to ten times the number of sealable parameters in the device, but not more than 1000 records are required. (Note: Does not require 1000 changes to be stored for each parameter.) |
S.1.4. Automatic Calibration. - A device may be fitted with an automatic or a semi-automatic calibration mechanism. Tins mechanism shall be mcorporated inside the device. After sealing, neither the mechanism nor the calibration process shall facilitate fraud.
S.1.5. Adjustable Components. - Adjustable components shall be held securely in adjustment and, except for a zero-load balance mechanism, shall be located within the housing of the element.
S.2. Design of Zero and Tare Mechanisms.
S.2.1. Zero Load Adjustment.
S.2.1.1. Automatic Zero-Setting Mechanism (Zero-tracking). - Except for automatic checkweighers, under normal operating conditions the maximum load that can be "rezeroed." when either placed on or removed from the platform all at once, shall be 1.0 scale division.
(Amended 2004)
S.2.1.2. Initial Zero-Setting Mechanism. - Except for automatic checkweighers. an initial zero-setting mechanism shall not zero a load m excess of 20 % of the maximum capacity of the automatic weighing system unless tests show that the scale meets all applicable tolerances for any amount of initial load compensated by tliis device within the specified range.
S.2.2. Tare. - On any automatic weighing system the value of the tare division shall be equal to the value of the division. The tare mechanism shall operate only in a backward direction (i.e.. in a direction of underregistration) with respect to the zero-load balance condition of the automatic weighing system. A device designed to automatically clear any tare value shall also be designed to prevent the automatic dealing of tare until a complete transaction has been radicated
Note: On a computing automatic weighing system, this requires the input of a unit price, the display of the unit price, and a computed positive total price at a readable equilibrium. Other devices require a ee .es transaction or lot run s be completed (Amended 2004)
S.3.1. Multiple Range and Multi-Interval Automatic Weighing System. The value of "e" shall be equal to the value of "d."
S.3.2. Load C ell Verification Interval Value. - The relationship of the value for the load cell verification scale interval. vm, to the scale division "d" for a specific scale installation shall be:
v < . where K is the number of load cells in the scale.
Note: When the value of the scale division "d" differs from the verification scale division "e" for the scale, the value of "e" must be used in the formula above.
S.3.3. - For automatic checkweighers, the value of "e" shall be specified by the manufacturer and may be larger than "d," but in no case can "e'1 be more than 10 times the value of "d."
S.4. Weight Indicators, Weight Displays, Reports, and Labels.
S.4.1. Additional Digits in Displays. - Auxiliary digital displays that provide additional digits for use dunng performance evaluation may be included on automatic checkweighers. However, in cases where these indications are not valid for determining the actual weight of a package (e.g.. only appropriate for use in statistical process control programs by users) they shall be clearly and distinctly differentiated from valid weight displays by indicating them to the user.
For example, the additional digits may be differentiated by color, partially covered by placing Crosshatch overlays on the display, or made visible only after the operator presses a button or turns a key to set the device in a mode which enables the additional digits
S.4.2. Damping. - An indicating element equipped with other than automatic recording elements shall be equipped with, effective means to permit the recording of weight values only when the indication is stable within pins or minus one scale division. The values recorded shall be within applicable tolerances.
S.4.3. Over Capacity Indication. - An mdicating or recording element shall not display nor record any7 values when the scale capacity is exceeded by nine scale divisions.
S.4.4. Label Printer. - A device that produces a printed ticket to be used as the label for a package shall print all values digitally and of such size, style of type, and color as to be clear and conspicuous on the label.
S.4.1. Label Printing. - If an automatic checkweigher prmts a label containing weight information diat will be used in a commercial transaction, it must conform to all of the requirements specified for weigh-labelers so that the printed ticket meets appropriate requirements.
S.5. Accuracy Class.
S.5.1. Marking. - Weigh-labelers and automatic checkweighers shall be Class HI devices and shall be marked accordingly, except that a weigh-labeler marked Class HIS may be used in package shipping applications. (Amended 1997)
S.6. Parameters for Accuracy Classes. - The number of divisions for device capacity7 is designated by the manufacturer and shall comply with parameters shown in Table S.6.
Table S.6. Parameters for Accuracy Classes |
|
|
Number of divisions (n) |
Class |
Value of the verification division (4-a¥ e) |
Minimum |
Maximum |
SI Units |
III |
0.1 to 2g inclusive |
100 |
10 000 |
equal to or greater than 5g |
500 |
10 000 |
INCH-POUND Units |
in |
0.0002 lb to 0.005 lb: inclusive |
100 |
10 000 |
0.005 ozto 0.125 oz. inclusive |
100 |
10 000 |
equal to or greater than 0.01 lb |
500 |
10 000 |
equal to or greater than 0.25 oz |
500 |
10 000 |
HIS |
greater than 0.01 lb |
100 |
1000 |
greater than 0.25 oz |
100 |
1000 |
For Class III devices, the value of "e" is specified by the manufacturer as marked on the device; "d" shall not be smaller than 0.1 "e." "e" shall be differentiated from "d" by size, shape, or color. (Amended 2004) |
S.7. Marking Requirements. [See also G-S.l., G-S.4., G-S.6., G-S.7., G-U.2.1.1., and UR.3.3.]
S.7.1. Location of Marking Information. - Automatic weighing systems which are not permanently attached to an indicating element, and for which the load-receiving element is the only part of the weighing.load-receiving element visible after installation, may have the marking information required in G-S.l. of the General Code and Table S.7.a. and S.7.b. of the Automatic Weighing Systems Code located in an area that is accessible only through the use of a tool; provided that the information is easily accessible (e.g.. the information may appear on the junction box under an access plate). The identification information for these automatic weighing systems shall be located on the
(ii) stable while in motion, hence the length and width of a puck or package should be greater than its height.
(b) For type evaluation the manufacturer shall supply the test pucks or packages for each range of test loads. (Amended 1997)
N.1.2. Accuracy of Test Pucks 01 Packages. - The error in any test puck or package shall not exceed one-fourth (1/4) of me acceptance tolerance. If packages are used to conduct field tests on automatic weighing systems, the package weights shall be determined on a reference scale or balance with an inaccuracy that does not exceed one-fifth (1/5) of the smallest tolerance that can be applied to the device under test.
N.1.3. Verification (Testing) Standards. - Field standard weights shall comply with requirements of N1ST Handbook 105-1 (Class F) or the tolerances expressed in Fundamental Considerations, paragraph 3.2. (i.e., one-third of the smallest tolerance applied).
N.1.4. Radio Frequency Interference (RFI) and Other Electromagnetic Interference Susceptibility, Field Evaluation. - An RFI test shall be conducted at a given installation when the presence of RFI lias been verified and characterized if those conditions are considered "usual and customary." f Added 20041
N.1.5. Tests Loads. - A performance test shall consist of four separate test rims conducted at different test loads according to Table N. 3r2-l.?,
Table N. 3,21.5. Test Loads |
At or near minimum capacity |
At or near maximum capacity |
At two (21 critical points between minimum and maximum capacity |
Test may be conducted at other loads if the device is intended for use at other specific capacities |
N.1.6. Influence Factor Testing. - Influence factor testing shall be conducted statically.
N.2. Test Procedures - YVeigh-Labelers. - If the device is designed for use in s a non-automatic weighing mode, it shall be tested ss in the non-automatic mode according to Handbook 44 Section 2.20 Scales Code.
Note: If the device is designed for only automatic weighing, it shall only be tested
automatically.
(Amended 2004)
N.2.1. Non-automatic Tests.
N.1.12. Increasing-Load Test. - The increasing-load test shall be conducted with the test loads approximately centered on the load-receiving element of the scale.
N.1.22 Decreasing-Load Test. - The decreasing-load test shall be conducted with the test loads approximately centered on the load-receiving element of the scale.
N.1.32. Shift Test. - To determine the effect of off-center loadmg. a test load equal to one-half (Vi) maximum capacity shall be placed in the center of each of the four points equidistant between the center and front, left. back, and nght edges of the load receiver.
N.1.42.. Discrimination Test. - A discrimination test shall be conducted with the weighing device in equilibrium at zero load and at maximum test load, and under- controlled conditions in which environmental factors are reduced to the extent that they will not affect the results obtained. This test is conducted from just below the lower edge of the zone of uncertainty for increasing load tests, or from just above the upper edge of the zone of uncertainty for decreasing-load tests.
N.1.52. Zero-Load Balance Change. - A zero-load balance change test shall be conducted on all automatic weighing systems after the removal of any test load. The zero-load balance should not change by more than the minimum tolerance applicable. (Also see G-UR.4.2.)
-(Amended 2004)
N.2.2. Tteld Automatic Test Procedures.
N.2.2.1. Tests Non-automatic . - If the automatic weighing system is designed to operate nou-aiitomaticallv. and used in that manner, during normal use operation, it shall be tested non-automaticallv using mass standards. The device shall not be tested non-antoinaticallv if it is used only iii the automatic mode.
N.2.2.2. An to ma ti c Tests. - The device shall be tested at the normal operating speed using packages. Test runs should be conducted using at least two test loads distributed over its normal weighing range (e.g.. -at near the lowest and highest ranges m which the device is typically operated.) Each test load should be tun a minimum of 10 consecutive times. (Amended 2004J
N.3. Test Procedures - Automatic Checkweiglier.
N.3.1 Tests Non-Automatic. - If the scale is designed to operate tion
automatically during normal user operation, it shall be tested non-antoinaticallv according to paragraphs N.2.1.1. Increasing Load Tests through X.2.1.5. Zero-Balance Change -s, (Amended 2004)
N.3.2. - Automatic Tests. - The device shall be tested at the highest speed in each weight range using standardized test pucks or packages. Test inns shall be conducted using twofeuf- test loads. The number of consecutive test weighments shall one-half (12) of those specified e ese m Table N.3A2. but not less than 10. (Amended 2004)
Table N.3.4.2. Number of Sample Weights per Test for Automatic C heckweighers |
Weighing Range m = mass of test load |
Number of sample weights per test |
20 divisions < m < 10 kg 20 divisions < m < 22 Lb |
SO |
10 kg <m<25 kg 22 lb <na < 55 lb |
32 |
25kg<m< 100 kg 55 1b<m<220lb |
20 |
100 kg (220 lb) <m |
10 |
T. Tolerances
T.1. Principles.
T.1.1. Design. - The tolerance for a weighing device is a performance requirement independent of the design principle used.
T.1.2. Scale Division. - The tolerance for a weighing device is related to the value of the scale division (d) or the value of the verification scale division (e) and is generally expressed m terms of d or e. The random tolerance for automatic clieckweighers is expressed in terms of Maximum Allowable Variance (MAV).
T.2. Tolerance Application.
T.2.1. General. - The tolerance values are positive (-) and negative (-) with the weighing device adjusted to zero at no load. When tare is in use. the tolerance values are applied from the tare zero reference; the tolerance values apply to certified test loads only.
T.2.2. Type Evaluation Examinations. - Tor type evaluation examinations, the tolerance values apply to increasing and decreasing load tests within the temperature, and power supply, eese specified in T.7. Influence Factors, f Amended 2004)
T.2.3. Multiple Range and Multi-Interval Automatic Weighing System. - For multiple range and multi-interval devices, the tolerance values are based on the value of the scale division of the range in use.
T.3. Tolerance Values.
T.3.1. Tolerance Values - Class III Weigh-Labeler. (See Section T.3.2. Class MS Weigh-Labelers)
T.3.1.1. Non-automatic Tests. - Tolerance values shall be as specified in Table T.3. Class in -Tolerances in Divisions. (Amended 2004)
T.3.1.2. Auto ma tic Tests. - Acceptance tolerance values shall be the same as maintenance tolerance values specified in Table T.3.. Class III - Tolerances in Divisions. (Amended 20041
Table T.3. Class III - Tolerance in Divisions (4e) |
Test Load in Divisions |
Tolerance in Divisions |
Class III |
Acceptance |
Maintenance |
0-500 |
= 0.5 |
= 1 |
501 -2000 |
= 1 |
= j |
2001 - 4000 |
= 15 |
±3 |
4001 + |
= 2.5 |
= 5 |
T.3.2. Tolerance Values - Class HIS Weigh-labelets in Package Shipping Applications.
(Added 1997)
T.3.2.1. £htfie->i'oii-automatic Tests. - Tolerance values shall be as specified in Table T.3.2.1. Statie Non-automatic Tolerances for Class HIS Weigh-labelers. (Amended 20041
T.3.2.2. Automatic Tests. - Tolerance values specified in Table T.3.2.2. Dynamic Tolerances for Class HIS Weigh-Labelers shall be applied. (Amended 2004)
Table T.3.2.1.-Sortie Non-automatic Tolerance for Class HIS Weigh-labelers |
Test Load in Divisions |
Tolerance in Divisions |
Class HIS |
Acceptance |
Maintenance |
0-50 |
±0.5 |
±1 |
51-200 |
= 1 |
= 2 |
201 - 1000 |
± 1.5 |
±3 |
(Added 1997) fAmended 20041
Table T.3.2.2. DvnninicAutomatic Tolerance for Class HIS Weigh-labelers |
Test Load in Divisions |
Tolerance in Divisions |
Class HIS |
Acceptance |
Maintenance |
0-50 |
= 1.5 |
= 2 |
51-20 |
= 2 |
= 3 |
201 - 1000 |
= 2.5 |
= 4 |
(Added 19971 (Amended 20041
T.3.3. Tolerance Values. - Automatic Check-weighers.
T.3.3.1. Laboratory Tests for Automatic Checkweighers.
T.3.3.1.1. -StfttteXon-auto mark Tests. - The acceptance tolerance values specified in Table T.3., Class IH-Tolerances m Divisions, shall be applied. (Amended 20041
T.3.3.1.2. Automatic Tests.
(a) The systematic error for each test run must be within the acceptance tolerances for the test load as specified in Table N. 3s2
r 1.5.
(b) 'The standard deviation of the results shall not exceed one-ninth (1/9) of the Maximum Allowable Variation (MAV) for specific package weights (3 standard deviations cannot exceed one-third (1/3) of the MAV value) as required in the 4th
latest Edition of NIST Handbook 133. This value does not change regardless of whether acceptance, or maintenance tolerances are being applied to the device under test.
(Amended 20041
(i) For U.S. Department of Agriculture (USD A) inspected meat and poultry products packaged at a plant subject to inspection by the USDA Food Safety and Inspection Service, use Handbook 133 Table 2-9, U.S. Department of Agriculture. Meat and Poultry, Groups and Lower Limits for Individual Packages, or
(ii) for all other packages with a labeled net quantity in terms of weight use Handbook 133 Table 2-5. Maximum Allowable Variations for Packages Labeled by Weight.
(iii) For all packages with a labeled net quantity in terms of liquid or dry volume use Handbook 133 Table 2-6. Maximum Allowable Variations for Packages Labeled by Liquid or Dry Volume.
(Amended 2004)
T.3.3.2. Field Tests for Automatic Clieckweighers.
T.3.3.2.1. StatieNon-auroitinric Test Tolerances. - The tolerance values shall be as specified in Table T.3., Class Ill-Tolerances in Divisions.
T.3.3.2.2. Aiitotnatic Test Tolerances. -
(a) The systematic error requirement is not applied in a field test.
(b) The standard deviation of the test results shall not exceed one-ninth (1/9) of the Maximum Allowable Variation (MAV) for specific package weights (3 standard deviations cannot exceed one-tlui'd (1/3) of the MAV value) as required in the 44b
Latest Edition of NIST Handbook 133.
This value does not change regardless of whether acceptance or maintenance tolerances are being applied to the device under test. (Amended 2004)
(i) For U.S. Department of Agriculture (USD A) inspected meat and poultry products packaged at a plant subject to inspection by the USDA Food Safety and Inspection Service, use Handbook 133 Table 2-9, U.S. Department of Agriculture, Meat and Poultry, Groups and Lower Limits for Individual Packages, or
(ii) For all other packages with a labeled net quantity in terms of weight use Handbook 133 Table 2-5, Maxmium Allowable Variations for Packages Labeled by Weight.
(iii) For all packages with a labeled net quantity in terms of liquid or dry volume use Handbook 133 Table 2-6. Maximum Allowable Variations for Packages Labeled by Liquid or Dry Volume.
T.4. Agreement of Indications. - In the case of a weighing system equipped with more than one indicating element or indicating element and recording element combination, the difference in the weight value indications of any load shall not be greater- than the absolute value of the applicable tolerance for that load, and shall be w;ithin tolerance limits.
T.5. Repeatability. - The results obtained from several weighings of the same load under reasonably ^tatte-constant test conditions shall agree within the absolute value of the maintenance tolerance for that load, and shall be withm applicable tolerances. (Amended 2004)
T.6. Discrimination. - A test load equivalent to 1.4 d shall cause a change in the indicated or recorded value of at least 2.0 d. Tins requires the zone of uncertainty to be not greater than 0.3 d (See N._S2.1A)
T.7. Influence Factors. - The following factors are applicable to tests conducted under controlled conditions only.
T.7.1. Temperature. - Devices shall satisfy the tolerance requirements under the following temperature conditions:
T.7.1.1. - Ef not specified in the operating instructions or if not marked on the device, the temperature limits shall be: -10 SC to 40 3C (14 °F to 104 T)
T.7.1.2. - If temperature limits are specified for the device, the range shall be at least 30 °C (54 °F).
T.7.1.3. Temperature Effect on Zero-Load Balance. - The zero-load indication shall not vary by more than one division per 5 °C (9 °F) change in temperature.
T.7.1.4. Operating Temperature. - The indicating or recording element shall not display nor record any usable values until the operating temperature necessary for accurate weighing and a stable zero balance condition have been attained.
T.7.2. Electric Power Supply.
(a) ee
Automatic weighing systems that operate using alternating current must perform within the conditions defined in paragraphs T3. through T.N.6.. inclusive, Iroin -15 ° o to -10 Q-o of the marked nominal Line voltage(s) at 60 Hz. or the voltage range marked bv the manufacturer, at 60 Hz.ees ee seeses ----s s --
(b)
Automatic weighing systems that operate using DC current must perform within the conditions defined in paragraphs T3. through T.N.6., inclusive, from minimum operating voltage to - 20 a'o of the voltage marked on the instrument (nominal voltage).
(c)
Batten-operated electronic automatic weighing systems with external or plng-in power supply (AC or DC) shall either continue to function correctly or not indicate anv weight values if the voltage is below the manufacturer's specified value, the latter being larger or eciual to the minimum operating voltage.
Note: The minimum operating voltage is defined as the lowest possible operating voltage before the automatic weighing no longer does not indicate nor records weigh values.
Note: This requirement applies only to metro logically significant voltage supplies. (Amended 2001)
-s ss s s(Amended 2004)
T.7.3.2. Power Interruption. - A power interruption shall not cause an indicating or recording element to display or record any values outside the applicable tolerance limits.
T.8. Radio Frequency Interference (RFI) and Other Electromagnetic Interference Susceptibility. - The difference between the weight indication with the disturbance and the weight indication without the disturbance (see also N.1.4.) shall not exceed one scale division (d) or the equipment shall: (Amended 2004)
(a) blank the indication, or
(b) provide an error message, or
(c) the indication shall be so completely unstable that it could not be interpreted, or transmitted into memory or to a recording element, as a correct measurement value.
UR. User Requirements
UR.1. Selection Requirements. - Equipment shall be suitable for the service in which it is used with respect to elements of its design, including but not limited to, its capacity, number of scale divisions, value of the scale division or verification scale division, minimum capacity, and computing capability.
UR.1.1. General. - Automatic Weighing Systems shall be designated by the manufacturer for that service.
UR.l.2. 'Value of the Indicated and Recorded Scale Division. - The value of the division as recorded shall be the same as the division value indicated.
UR.2. Installation Requirements.
UR.2.1. Protection From Environmental Factors. - The indicating elements, the lever system or load cells, and the load-receiving element of a permanently installed scale, and the indicating elements of a scale not intended to be permanently installed, shall be adequately protected from environmental factors such as wind, weather, and RFI that may adversely affect the operation or performance of the device.
UR.2.2. Foundation, Supports, and Clearance. - The foundation and supports of any scale installed in a fixed location shall be such as to provide strength, rigidity, and permanence of all components, and clearance shall be provided around all live parts to the extent that no contacts may result when the load-receiving element is empty, nor throughout the weighing range of the scale.
UR.2.3. Entry and Departure From Weighing Area. - The belt or other conveyance mat introduces the weighed load to the weighing zone and that carries the weighed load away from the weighing zone shall be maintained per the manufacturers recommendations.
UR.3. Use Requirements.
UR.3.1. Minimum Load. - The minimum load shall be as specified by the manufacturer; but not less than 20 divisions smce the use of a device to weigh light loads is likely to result in relatively large errors.
UR.3.1.1. Minimum Load for Class HIS Weigh-labelers. - The minimum load shall be as specified by the manufacturer, but not less than 10 divisions since the use of a device to weigh light loads is likely to result in relatively large errors. (Added 1997)
UR.3.2. Maximum Load. - An automatic weighing system shall not be used to weigh a load of more than theits maximum capacity e ee. (Amended 2004)
UR.3.3. Special Designs. - An automatic weighing system designed and marked for a special application shall not be used for other than its intended purpose.
UR.3.4. Use of Manual Gross Weight Entries. - Manual entries are peiimtted only when a device or system is generating labels for standard weight packages.
LR.4. Maintenance Requirements.
UR.4.1. Balance Condition. - If an automatic weighing system is equipped with a zero-load display, the zero-load adjustment of an automatic weighing system shall be maintained so mat the device indicates or records a zero-balance condition.
UR.4.2. Level Condition. - If an automatic weighing system is equipped with a level-condition indicator, the automatic weighing system shall be maintained in level.
CR.4.3. Automatic Weighing System Modification. - The length or the width of the load-receiving element of an automatic weighing system shall not be increased beyond the manufacturer's design dimension, nor shall the capacity of an automatic weighing system be increased beyond its design capacity by replacing or modifying the original primary indicating or recording element with one of a higher capacity, except when the modification has been approved by competent engineering authority, preferably that of the engineering department of the manufacturer of the automatic weighing system, and by the weights and measures authority having jurisdiction over the automatic weighing system.