| Parameter |
Symbol |
Criteria |
Critical Use* |
| Alkalinity |
Alk |
Minimum 20 mg/1 as CaC03, except where natural conditions are less. Where discharges are to waters with 20 mg/1 or less alkalinity, the discharge should not further reduce the alkalinity of the receiving waters. |
CWF, WWF, TSF, MF |
| Ammonia Nitrogen |
Am |
In freshwater, the concentration of total ammonia nitrogen (TAN) shall not exceed (more than once in three years on average), the concentration calculated (in milligrams of TAN per liter) by the following: 1-hour average Criteria Maximum Concentration (CMC) acute criterion equation: 30-day rolling average Criteria Continuous Concentration (CCC) chronic criterion equation: The highest 4-day average within the 30-day averaging period should not be more than 2.5 times the CCC (e.g. 2.5 x 0.2 mg TAN/L at pH 9 and 20°C or 0.5 mg TAN/L) more than once in 3 years on average. |
CWF, WWF, TSF, MF |
| The pH and temperature used to derive the appropriate ammonia criteria shall be determined by instream measurements or best estimates, based on reference waters that are representative of the median pH and temperature of the receiving water. Instream measurements for pH and temperature will be gathered using department data collection protocols. |
| Bacteria |
Bac1 |
(Escherichia coli colony forming units per 100 milliliters (CFU per 100 ml)) During the swimming season (May 1 through September 30), the maximum E. coli level shall be a geometric mean of 126 CFU per 100 ml. The geometric mean for the samples collected in the waterbody should not be greater than 126 CFU per 100 ml in any 30-day interval. There should not be greater than a 10% excursion frequency of 410 CFU per 100 ml for the samples collected in the same 30-day duration interval. (Fecal coliforms/100 ml) For the remainder of the year, the maximum fecal coliform level shall be a geometric mean of 2,000 CFU per 100 ml based on a minimum of five consecutive samples collected on different days during a 30-day period. |
WC |
| Chloride |
Ch |
Maximum 250 mg/1. |
PWS |
| Color |
Col |
Maximum 75 units on the platinum-cobalt scale; no other colors perceptible to the human eye. |
PWS |
| Dissolved Oxygen |
|
The following specific dissolved oxygen criteria recognize the natural process of stratification in lakes, ponds and impoundments. These criteria apply to flowing waters and to the epilimnion of a naturally stratified lake, pond or impoundment. The hypolimnion in a naturally stratified lake, pond or impoundment is protected by the narrative water quality criteria in 93.6 (relating to general water quality criteria). For nonstratified lakes, ponds or impoundments, the dissolved oxygen criteria apply throughout the lake, pond or impoundment to protect the critical uses. |
|
DO1 |
For flowing waters, minimum daily average 6.0 mg/l; minimum 5.0 mg/l. For lakes, ponds and impoundments, minimum 5.0 mg/l. |
CWF HQ-WWF HQ-TSF |
|
DO2 |
Minimum daily average 5.0 mg/l; minimum 4.0 mg/l. |
WWF |
|
DO3 |
For the period February 15 to July 31 of any year, minimum daily average 6.0 mg/l; minimum 5.0 mg/l. For the remainder of the year, minimum daily average 5.0 mg/l; minimum 4.0 mg/l. |
TSF |
|
DO4 |
Minimum 7.0 mg/l. |
HQ-CWF |
| Fluoride |
F |
Daily average 2.0 mg/l. |
PWS |
| Iron |
Fe1 |
30-day average 1.5 mg/l as total recoverable. |
CWF, WWF, TSF, MF |
|
Fe2 |
Maximum 0.3 mg/l as dissolved. |
PWS |
| Manganese |
Mn |
Maximum 1.0 mg/l, as total recoverable. |
PWS |
| Nitrite plus Nitrate |
N |
Maximum 10 mg/l as nitrogen. |
PWS |
| Osmotic Pressure |
OP |
Maximum 50 milliosmoles per kilogram. |
CWF, WWF, TSF, MF |
| pH |
pH |
From 6.0 to 9.0 inclusive. |
CWF, WWF, TSF, MF |
| Phenolics (except § 307(a)(1) ( 33 U.S.C.A. § 1317(a)(1) ), Priority Pollutants) |
Phen |
Maximum 0.005 mg/l. |
PWS |
| Sulfate |
Sul |
Maximum 250 mg/l. |
PWS |
| Temperature |
|
Maximum temperatures in the receiving water body resulting from heated waste sources regulated under Chapters 92, 96 and other sources where temperature limits are necessary to protect designated and existing uses. Additionally, these wastes may not result in a change by more than 2°F during a 1-hour period. |
See the following table. |