1809.5 Frost protection.
Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected by one or more of the following methods:
1. See Rhode Island Frost Depth values in Table 1608.1. and Figure 1608.1
2. Construction in accordance with ASCE 32; 05
3. Erecting on solid rock
Exception: Free-standing buildings meeting all of the following conditions shall not be required to be protected:
1. Classified in Occupancy Category I, in accordance with section 1604.5;
2. Area of six hundred (600) square feet (56 M
2) or less for light-frame construction or four hundred (400) square feet (37 m
2) or less for other than light-frame construction; and
3. Eave height of ten feet (10') (3048 mm) or less
Footings shall not bear on frozen soil unless such frozen condition is of a permanent character.