Login

Mich. Admin. Code R. 325.2653 : State Police —Traffic Safety Division —Tests for Breath Alcohol — Equipment accuracy

Rule 3.

(1) An appropriate class operator who has been certified in accordance with R 325.2658 shall verify an evidential breath alcohol test instrument for accuracy at least once each calendar week, or more frequently as the department may require. Alternatively, a pre-programmed self-test for accuracy may be initiated by the evidential breath alcohol test instrument and recorded by an appropriate class operator who has been certified in accordance with R 325.2658 if the instrument is so equipped and programmed. The tests for accuracy are not required to be performed within 7 days of each other. The test for accuracy shall be made using an alcohol standard that is approved by the department. For the evidential breath alcohol test instrument to meet the requirements for accuracy, a test result not exceeding +/- 5% shall be obtained when using a controlled device. Controlled devices include both of the following:
(a) Wet bath device that delivers an alcohol vapor concentration test result of .080 grams of alcohol per 210 liters of vapor.
(b) Compressed alcohol gas device that delivers a test result of .080 grams of alcohol per 210 liters of vapor after applying applicable altitude or topographic elevation correction factor supplied by the manufacturer. The correction factor may be applied by the operator or by the evidential breath alcohol test instrument if so pre-programmed.
(2) An appropriate class operator who has been certified in accordance with R 325.2658 shall verify for accuracy a preliminary breath alcohol test instrument at least monthly, or more frequently as the department may require. The test for accuracy shall be made using an alcohol standard that is approved by the department. For the preliminary breath alcohol test instrument to meet the requirements for accuracy, a test result not exceeding +/- 5% shall be obtained when using a controlled device. Controlled devices include both of the following:
(a) Wet bath device that delivers an alcohol vapor concentration of .080 grams of alcohol per 210 liters of vapor.
(b) Compressed alcohol gas device that delivers a test result of .080 grams of alcohol per 210 liters of vapor after applying applicable altitude or topographic elevation correction factor supplied by the manufacturer. The correction factor may be applied by the operator or by the preliminary breath alcohol test instrument calibration station if so pre-programmed.
(3) Approved evidential breath alcohol test instruments shall be inspected, verified for accuracy, and certified as to their proper working order within 120 days of the previous inspection by either an appropriate class operator who has been certified in accordance with R 325.2658 or a manufacturer-trained representative approved by the department.

Mich. Admin. Code R. 325.2653

1979 AC; 1984 AACS; 1988 AACS; 1992 AACS; 1994 AACS; 2003 AACS; 2007 AACS; 2010 AACS; 2018 MR 2, Eff. 1/23/2018