TABLE II
MAXIMUM HORIZONTAL DISTANCE BETWEEN EDGES OF SHEETING
Excavation Depth Type of Soil 5 to 10 ft. Over 10 to 15 Over 15 to 20 ft. ft. Stiff cohesive soil Tight Tight Tight Noncohesive soil 2 feet Tight Tight Soft cohesive or wet flowing Tight Tight Tight soilTABLE III
MINIMUM SIZES OF STRINGERS AND BRACES
Narrow Trenches--Horizontal Cross-Braces Not Longer Than Four Feet
[Note: The following TABLE/FORM is too wide to be displayed on one screen. You must print it for a meaningful review of its contents. The table has been divided into multiple pieces with each piece containing information to help you assemble a printout of the table. The information for each piece includes: (1) a three line message preceding the tabular data showing by line # and character # the position of the upper left-hand corner of the piece and the position of the piece within the entire table; and (2) a numeric scale following the tabular data displaying the character positions.] ******************************************************************************* ******** This is piece 1. -- It begins at character 1 of table line 1. ******** ******************************************************************************* Trench Type of Vertical Depth Soil Spacing of Stringers 4 Feet Stringers Braces 5 to 10 Stiff 4 ft. max. 4 x 4 4 x 4 ft. cohesive Noncohesive 4 ft. max. 6 x 6 or 4 x 4 4 x8 Soft 4 ft. max. 6 x 6 4 x 4 cohesive and wet flowing Over 10 Stiff 4 ft. max. 4 x 6 4 x 4 to 20 cohesive ft. and nonco- hesive Soft 4 ft. max. 6 x 8 6 x 6 cohesive and wet flowing 1...+...10....+...20....+...30....+...40....+...50....+. ******************************************************************************* ******* This is piece 2. -- It begins at character 57 of table line 1. ******** ******************************************************************************* Horizontal Spacing of Cross-Braces 6 Feet 8 Feet 12 Feet Stringers Braces Stringers Braces Stringers Braces 6 x 6 or 4 x 4 6 x 6 4 x 4 8 x 8 4 x 6 4 x8 6 x 6 4 x 4 6 x 8 4 x 4 8 x 10 6 x 6 6 x 10 4 x 6 8 x 10 6 x 6 10 x 12 6 x 8 6 x 6 4 x 4 8 x 8 or 4 x 6 10 x 10 6 x 6 6 x10 8 x 10 6 x 8 10 x 12 8 x 8 [FN*] [FN*] 57......+...70....+...80....+...90....+....0....+...10.. ******************************************************************************* ******* This is piece 3. -- It begins at character 1 of table line 23. ******** ******************************************************************************* Over 20 For any trench over 20 feet in depth ft. a professional engineer licensed to specifications for any such bracing by the commissioner. 1...+...10....+...20....+...30....+...40....+... ******************************************************************************* ******* This is piece 4. -- It begins at character 49 of table line 23. ******* ******************************************************************************* the sheeting, shoring and bracing systems shall be designed by practice in the State of New York. A copy of the plans and system shall be kept at the job site available for examination 49....+...60....+...70....+...80....+...90....+....0....+...10.. ******************************************************************************* ******* This is piece 5. -- It begins at character 1 of table line 27. ******** *******************************************************************************FN* Sizes of timber for such conditions become excessive. A special structure engineer licensed to practice in the State of New York shall be constructed condition involved.
1...+...10....+...20....+...30....+...40....+...50....+...60....+...70....+..
******************************************************************************* ******* This is piece 6. -- It begins at character 78 of table line 27. ******* ******************************************************************************* designed by a professional and used for the specific 78.....+...90....+....0....+...10..Note: Timber sizes are nominal or trade dimensions.
N.Y. Comp. Codes R. & Regs. Tit. 12 § 23-4.4