Login

30 CFR 75.603 : Mineral Resources (§ 1.1 To Parts 1291-1299) — (§ 1.1 To Parts 105-199) — Mine Safety And Health Administration, Department Of Labor (§ 1.1 To Parts 105-199) — Coal Mine Safety And Health (§ 70.1 To § 90.301) — Mandatory Safety Standards - Underground Coal Mines (§ 75.1 To § 75.1916) — Trailing Cables (§ 75.600 To § 75.607) — Temporary splice of trailing cable.

4 Aug 2016

[Statutory Provision]

One temporary splice may be made in any trailing cable. Such trailing cable may only be used for the next 24-hour period. No temporary splice shall be made in a trailing cable within 25 feet of the machine, except cable reel equipment. Temporary splices in trailing cables shall be made in a workmanlike manner and shall be mechanically strong and well insulated. Trailing cables or hand cables which have exposed wires or which have splices that heat or spark under load shall not be used. As used in this section, the term “splice” means the mechanical joining of one or more conductors that have been severed.

30 CFR 75.603